Roads and highways lighting should comply with external lighting norms so to reduce the number of accidents at night, provide safe movement for pedestrians and convenience for drivers. In this case the sufficient luminous power for pedestrians is 2 lx while movement of transport requires 5 - 20 lx. It is important to install correct road lighting system that provides drivers with maximum visibility and is not too glare at the same time. For this purpose a special "light corridor" should be designed where the direction of street lights leads to the safe traffic of both vehicles and pedestrians.

Proper road lighting

The technology of LEDs is considered to be an effective and beneficial for the road lighting. These lights are characterized by high power, durability, and economy.

LED road lighting is calculated in the same way as any other lighting project and each installation must be selected and set for each road separately. High-power equipment is preferred to use on the main roads and highways, while lighting of 70-120W power is enough for industrial and residential areas. For example, the lightings with a capacity of 150 to 270 W and equipped with a frosted diffuser are best used for wide highways. This allocation allows to distribute light efficiently and save costs on excessive lighting.

We provide services for the development of lighting systems that meet city requirements, ensure road lighting modernisation and electricity cost savings.

RGL Compact Genius 150-180 W L140х60

Weight 8 kg
Dimensions 360х323х163 mm
Parameters Power, W Luminous flux, lm Illuminance from height in lx
25 m 15 m 12 m
RGL-180 L140х60 180 21 600 - - 18
RGL-150 L140х60 150 18 600 - - 15

* * illuminance in case of 25 m spacing between illumination poles

RGL Standart Genius 210-400 Вт. L140х60

Weight 13 kg.
Dimensions 670х370х178 mm
Parameters Power, W Luminous flux, lm Illuminance from height in lx
25 m 15 m 12 m
RGL-400 L140х60 400 21 600 60 30 40
RGL-270 L140х60 270 29 000 40 20 27
RGL-180 L140х60 180 18 600 30 15 21

* * illuminance: for a height of 12 m — in case of 25 m spacing between illumination poles, for a height of 15 m — in case of 30 m spacing between illumination poles, for a height of 25 m — at a distance of 20 meters from bracket post with 6 luminaires

The light level depending on the power
  • RGL Standart L140
  • RGL-400 60 lx
  • RGL-270 40 lx
  • RGL-210 30 lx
30 m spacing of illumination poles
  • RGL Standart L140
  • RGL-400 30 lx
  • RGL-270 20 lx
  • RGL-210 15 lx
25 m spacing of illumination poles.
  • RGL Standart L140
  • RGL-180 18 lx
  • RGL-150 15 lx
  • RGL Standart L140
  • RGL-400 40 lx
  • RGL-270 27 lx
  • RGL-210 21 lx